1. Synthesis and application of an Nδ-acetyl-Nδ-hydroxyornithine analog: identification of novel metal complexes of deferriferrichrysin
Kazuya Kobayashi, Shinya Oishi, Yuka Kobayashi, Hiroaki Ohno, Hiroko Tsutsumi, Yoji Hata, Nobutaka Fujii Bioorg Med Chem. 2012 Apr 15;20(8):2651-5. doi: 10.1016/j.bmc.2012.02.033. Epub 2012 Feb 20.
Synthesis of Fmoc-protected N(δ)-acetyl-N(δ)-(tert-butoxy)-l-ornithine has revealed it to be a metal-chelating amino-acid precursor. This protected amino acid was compatible with the preparation of ferrichrome peptides by standard Fmoc-based solid-phase peptide synthesis. Evaluation of deferriferrichrysin for metal ion chelation revealed that zirconium(IV) and titanium(IV) formed complexes with deferriferrichrysin.
2. Feasibility of Multiple Examinations Using (68)Ga-Labelled Collagelin Analogues: Organ Distribution in Rat for Extrapolation to Human Organ and Whole-Body Radiation Dosimetry
Irina Velikyan, Ulrika Rosenström, Thomas N Bulenga, Olof Eriksson, Gunnar Antoni Pharmaceuticals (Basel). 2016 Jun 6;9(2):31. doi: 10.3390/ph9020031.
Objectives: Fibrosis is involved in many chronic diseases. It affects the functionality of vital organs, such as liver, lung, heart and kidney. Two novel imaging agents for positron emission tomography (PET) imaging of fibrosis have previously pre-clinically demonstrated promising target binding and organ distribution characteristics. However, the relevant disease monitoring in the clinical setup would require multiple repetitive examinations per year. Thus, it is of paramount importance to investigate the absorbed doses and total effective doses and thus, the potential maximum number of examinations per year. Methods: Two cyclic peptide (c[CPGRVMHGLHLGDDEGPC]) analogues coupled via an ethylene glycol linker (EG₂) to either 2-(4,7-bis(2-(tert-butoxy)-2-oxoethyl)-1,4,7-triazonan-1-yl)acetic acid (NO2A-Col) or 4-(4,7-bis(2-(tert-butoxy)-2-oxoethyl)-1,4,7-triazacyclononan-1-yl)-5-(tert-butoxy)-5-oxopentanoic acid (NODAGA-Col) were labelled with (68)Ga. The resulting agents, [(68)Ga]Ga-NO2A-Col and [(68)Ga]Ga-NODAGA-Col, were administered in the tail vein of male and female Sprague-Dawley rats (N = 24). An ex vivo organ distribution study was performed at the 5-, 10-, 20-, 40-, 60- and 120-min time points. The resulting data were extrapolated for the estimation of human organ and total body absorbed and total effective doses using Organ Level Internal Dose Assessment Code software (OLINDA/EXM 1.1) assuming a similar organ distribution pattern between the species. Time-integrated radioactivity in each organ was calculated by trapezoidal integration followed by a single-exponential fit to the data points extrapolated to infinity. The resulting values were used for the residence time calculation. Results: Ex vivo organ distribution data revealed fast blood clearance and washout from most of the organs. Although the highest organ absorbed dose was found for kidneys (0.1 mGy/MBq), this organ was not the dose-limiting one and would allow for the administration of over 1460 MBq per year for both [(68)Ga]Ga-NO2A-Col and [(68)Ga]Ga-NODAGA-Col. The total effective dose was the limiting parameter with 0.0155/0.0156 (female/male) mSv/MBq and 0.0164/0.0158 (female/male) mSv/MBq, respectively, for [(68)Ga]Ga-NO2A-Col and [(68)Ga]Ga-NODAGA-Col. This corresponded to the total amount of radioactivity that could be administered per year of 643 and 621 MBq before reaching the annual limit of 10 mSv. Thus, up to six examinations would be possible. The residence time and organ absorbed doses in liver and spleen were higher for [(68)Ga]Ga-NODAGA-Col as compared to [(68)Ga]Ga-NO2A-Col. Conclusion: The limiting parameter for the administered dose was the total effective dose that would allow for at least six examinations per year that might be sufficient for adequate disease monitoring in longitudinal studies and a routine clinical setup.
3. Smartphone-assisted detection of nucleic acids by light-harvesting FRET-based nanoprobe
Caterina Severi, Nina Melnychuk, Andrey S Klymchenko Biosens Bioelectron. 2020 Nov 15;168:112515. doi: 10.1016/j.bios.2020.112515. Epub 2020 Aug 15.
Point-of-care assays for optical detection of biomolecular markers attract growing attention, because of their capacity to provide rapid and inexpensive diagnostics of cancer and infectious diseases. Here, we designed a nanoprobe compatible with a smartphone RGB camera for detection of nucleic acids. It is based on light-harvesting polymeric nanoparticles (NPs) encapsulating green fluorescent donor dyes that undergo efficient Förster Resonance Energy Transfer (FRET) to red fluorescent acceptor hybridized at the particle surface. Green-emitting NPs are based on rhodamine 110 and 6G dyes paired with bulky hydrophobic counterions, which prevent dye self-quenching and ensure efficient energy transfer. Their surface is functionalized with a capture DNA sequence for cancer marker survivin, hybridized with a short oligonucleotide bearing FRET acceptor ATTO647N. Obtained 40-nm poly(methyl methacrylate)-based NP probe, encapsulating octadecyl rhodamine 6G dyes with tetrakis(perfluoro-tert-butoxy)aluminate counterions (~6000 dyes per NP), and bearing 65 acceptors, shows efficient FRET with >20% quantum yield and a signal amplification (antenna effect) of 25. It exhibits ratiometric response to the target DNA by FRET acceptor displacement and enables DNA detection in solution by fluorescence spectroscopy (limit of detection 3 pM) and on surfaces at the single-particle level using two-color fluorescence microscopy. Using a smartphone RGB camera, the nanoprobe response can be readily detected at 10 pM target in true color and in red-to-green ratio images. Thus, our FRET-based nanoparticle biosensor enables detection of nucleic acid targets using a smartphone coupled to an appropriate optical setup, opening the way to simple and inexpensive point-of-care assays.